Features

• High lumen output and efficacy typical
• Over 475 lm, 119 LPW @ 3000K, 90CRI, Tj = 85°C
• CCT range 2200K, 2400K, 2700K, 3000K, 3500K, 4000K, 5000K and 6500K
• 3 SDCM and 2 SDCM color binning standard
• Excellent optical emission uniformity and color over angle consistency
• Superior thermal conductivity for uniform heat spreading

 

Applications
• Hotel Lighting
• Spotlights/Track Lights
• Downlights
• Shop Lighting
• Hospitality Lighting
• Architectural and Specialty

 

Ordering Part Numbers -TE60 - 9V

The following tables describe products with typical flux and minimum flux measured at 480 mA and specified at Tj = 85°C. The values at 25°C are calculated and shown for reference only.

Minimum-

CRI²

CCT

Luminous Flux¹

Ordering Part Number

Typical Flux

(85°C)

Minimum

Flux (85°C)

Calculated

Typical

Flux (25°C)

3-step MacAdam Ellipse

2-step MacAdam Ellipse

90

2200K

390

365

430

CXM-4-22-90-9-TE60-F7-3

CXM-4-22-90-9-TE60-F7-2

90

2400K

425

395

465

CXM-4-24-90-9-TE60-F7-3

CXM-4-24-90-9-TE60-F7-2

80

2700K

515

480

565

CXM-4-27-80-9-TE60-F7-3

CXM-4-27-80-9-TE60-F7-2

90

460

425

505

CXM-4-27-90-9-TE60-F7-3

CXM-4-27-90-9-TE60-F7-2

95

385

355

420

CXM-4-27-95-9-TE60-F7-3

CXM-4-27-95-9-TE60-F7-2

80

3000K

545

505

600

CXM-4-30-80-9-TE60-F7-3

CXM-4-30-80-9-TE60-F7-2

90

475

440

520

CXM-4-30-90-9-TE60-F7-3

CXM-4-30-90-9-TE60-F7-2

95

405

375

445

CXM-4-30-95-9-TE60-F7-3

CXM-4-30-95-9-TE60-F7-2

80

3500K

555

515

610

CXM-4-35-80-9-TE60-F7-3

CXM-4-35-80-9-TE60-F7-2

90

485

455

535

CXM-4-35-90-9-TE60-F7-3

CXM-4-35-90-9-TE60-F7-2

95

420

395

465

CXM-4-35-95-9-TE60-F7-3

CXM-4-35-95-9-TE60-F7-2

80

4000K

565

525

625

CXM-4-40-80-9-TE60-F7-3

CXM-4-40-80-9-TE60-F7-2

90

500

465

550

CXM-4-40-90-9-TE60-F7-3

CXM-4-40-90-9-TE60-F7-2

95

445

415

490

CXM-4-40-95-9-TE60-F7-3

CXM-4-40-95-9-TE60-F7-2

80

5000K

575

535

635

CXM-4-50-80-9-TE60-F7-3

CXM-4-50-80-9-TE60-F7-2

90

495

460

545

CXM-4-50-90-9-TE60-F7-3

CXM-4-50-90-9-TE60-F7-2

95

465

435

515

CXM-4-50-95-9-TE60-F7-3

CXM-4-50-95-9-TE60-F7-2

80

6500K

560

520

615

CXM-4-65-80-9-TE60-F7-3

CXM-4-65-80-9-TE60-F7-2

90

500

465

550

CXM-4-65-90-9-TE60-F7-3

CXM-4-65-90-9-TE60-F7-2

 

Ordering Part Numbers - TE60 -18V

The following tables describe products with typical flux and minimum flux measured at 240 mA and specified at Tj = 85°C. The values at 25°C are calculated and shown for reference only.

Minimum-

CRI²

CCT

Luminous Flux¹

Ordering Part Number

Typical Flux

(85°C)

Minimum

Flux (85°C)

Calculated

Typical

Flux (25°C)

3-step MacAdam Ellipse

2-step MacAdam Ellipse

90

2200K

390

365

430

CXM-4-22-90-18-TE60-F7-3

CXM-4-22-90-18-TE60-F7-2

90

2400K

425

395

465

CXM-4-24-90-18-TE60-F7-3

CXM-4-24-90-18-TE60-F7-2

80

2700K

515

480

565

CXM-4-27-80-18-TE60-F7-3

CXM-4-27-80-18-TE60-F7-2

90

460

425

505

CXM-4-27-90-18-TE60-F7-3

CXM-4-27-90-18-TE60-F7-2

95

385

355

420

CXM-4-27-95-18-TE60-F7-3

CXM-4-27-95-18-TE60-F7-2

80

3000K

545

505

600

CXM-4-30-80-18-TE60-F7-3

CXM-4-30-80-18-TE60-F7-2

90

475

440

520

CXM-4-30-90-18-TE60-F7-3

CXM-4-30-90-18-TE60-F7-2

95

405

375

445

CXM-4-30-95-18-TE60-F7-3

CXM-4-30-95-18-TE60-F7-2

80

3500K

555

515

610

CXM-4-35-80-18-TE60-F7-3

CXM-4-35-80-18-TE60-F7-2

90

485

455

535

CXM-4-35-90-18-TE60-F7-3

CXM-4-35-90-18-TE60-F7-2

95

420

395

465

CXM-4-35-95-18-TE60-F7-3

CXM-4-35-95-18-TE60-F7-2

80

4000K

565

525

625

CXM-4-40-80-18-TE60-F7-3

CXM-4-40-80-18-TE60-F7-2

90

500

465

550

CXM-4-40-90-18-TE60-F7-3

CXM-4-40-90-18-TE60-F7-2

95

445

415

490

CXM-4-40-95-18-TE60-F7-3

CXM-4-40-95-18-TE60-F7-2

80

5000K

575

535

635

CXM-4-50-80-18-TE60-F7-3

CXM-4-50-80-18-TE60-F7-2

90

495

460

545

CXM-4-50-90-18-TE60-F7-3

CXM-4-50-90-18-TE60-F7-2

95

465

435

515

CXM-4-50-95-18-TE60-F7-3

CXM-4-50-95-18-TE60-F7-2

80

6500K

560

520

615

CXM-4-65-80-18-TE60-F7-3

CXM-4-65-80-18-TE60-F7-2

90

500

465

550

CXM-4-65-90-18-TE60-F7-3

CXM-4-65-90-18-TE60-F7-2

 

Ordering Part Numbers - TE60 - 36V

The following tables describe products with typical flux and minimum flux measured at 120 mA and specified at Tj = 85°C. The values at 25°C are calculated and shown for reference only.

Minimum-

CRI²

CCT

Luminous Flux¹

Ordering Part Number

Typical Flux

(85°C)

Minimum

Flux (85°C)

Calculated

Typical

Flux (25°C)

3-step MacAdam Ellipse

2-step MacAdam Ellipse

90

2200K

390

365

430

CXM-4-22-90-36-TE60-F7-3

CXM-4-22-90-36-TE60-F7-2

90

2400K

425

395

465

CXM-4-24-90-36-TE60-F7-3

CXM-4-24-90-36-TE60-F7-2

80

2700K

515

480

565

CXM-4-27-80-36-TE60-F7-3

CXM-4-27-80-36-TE60-F7-2

90

460

425

505

CXM-4-27-90-36-TE60-F7-3

CXM-4-27-90-36-TE60-F7-2

95

385

355

420

CXM-4-27-95-36-TE60-F7-3

CXM-4-27-95-36-TE60-F7-2

80

3000K

545

505

600

CXM-4-30-80-36-TE60-F7-3

CXM-4-30-80-36-TE60-F7-2

90

475

440

520

CXM-4-30-90-36-TE60-F7-3

CXM-4-30-90-36-TE60-F7-2

95

405

375

445

CXM-4-30-95-36-TE60-F7-3

CXM-4-30-95-36-TE60-F7-2

80

3500K

555

515

610

CXM-4-35-80-36-TE60-F7-3

CXM-4-35-80-36-TE60-F7-2

90

485

455

535

CXM-4-35-90-36-TE60-F7-3

CXM-4-35-90-36-TE60-F7-2

95

420

395

465

CXM-4-35-95-36-TE60-F7-3

CXM-4-35-95-36-TE60-F7-2

80

4000K

565

525

625

CXM-4-40-80-36-TE60-F7-3

CXM-4-40-80-36-TE60-F7-2

90

500

465

550

CXM-4-40-90-36-TE60-F7-3

CXM-4-40-90-36-TE60-F7-2

95

445

415

490

CXM-4-40-95-36-TE60-F7-3

CXM-4-40-95-36-TE60-F7-2

80

5000K

575

535

635

CXM-4-50-80-36-TE60-F7-3

CXM-4-50-80-36-TE60-F7-2

90

495

460

545

CXM-4-50-90-36-TE60-F7-3

CXM-4-50-90-36-TE60-F7-2

95

465

435

515

CXM-4-50-95-36-TE60-F7-3

CXM-4-50-95-36-TE60-F7-2

80

6500K

560

520

615

CXM-4-65-80-36-TE60-F7-3

CXM-4-65-80-36-TE60-F7-2

90

500

465

550

CXM-4-65-90-36-TE60-F7-3

CXM-4-65-90-36-TE60-F7-2

 

Ordering Part Numbers - TE62 Sensus (BBBL) - 9 V/18 V/36V

The following tables describe products with typical flux and minimum flux measured at typical current and specified at Tj = 85°C. The values at 25°C are calculated and shown for reference only.

Minimum-

CRI²

CCT

Luminous Flux¹

Ordering Part Number

Typical Flux

(85°C)

Minimum

Flux (85°C)

Calculated

Typical

Flux (25°C)

3-step MacAdam Ellipse

2-step MacAdam Ellipse

90

2700K

435

405

480

CXM-4-27-90-9-TE62-F7-3

CXM-4-27-90-9-TE62-F7-2

CXM-4-27-90-18-TE62-F7-3

CXM-4-27-90-18-TE62-F7-2

CXM-4-27-90-36-TE62-F7-3

CXM-4-27-90-36-TE62-F7-2

3000K

460

430

510

CXM-4-30-90-9-TE62-F7-3

CXM-4-30-90-9-TE62-F7-2

CXM-4-30-90-18-TE62-F7-3

CXM-4-30-90-18-TE62-F7-2

CXM-4-30-90-36-TE62-F7-3

CXM-4-30-90-36-TE62-F7-2

3500K

475

440

520

CXM-4-35-90-9-TE62-F7-3

CXM-4-35-90-9-TE62-F7-2

CXM-4-35-90-18-TE62-F7-3

CXM-4-35-90-18-TE62-F7-2

CXM-4-35-90-36-TE62-F7-3

CXM-4-35-90-36-TE62-F7-2

 

Ordering Part Numbers - TC61 -36V

The following tables describe products with typical flux and minimum flux measured at 120 mA and specified at Tj = 85°C. The values at 25°C are calculated and shown for reference only.

MinimumCRI²

CCT

Luminous Flux¹

Ordering Part Number

Typical Flux

(85°C)

Minimum Flux

(85°C)

Calculated

Typical

Flux (25°C)

3-step MacAdam Ellipse

90

2700K

450

415

495

CXM-4-27-90-36-TC61-F7-3

3000K

470

435

515

CXM-4-30-90-36-TC61-F7-3

3500K

480

445

530

CXM-4-35-90-36-TC61-F7-3

4000K

490

455

540

CXM-4-40-90-36-TC61-F7-3

95

2700K

380

350

420

CXM-4-27-95-36-TC61-F7-3

3000K

400

370

440

CXM-4-30-95-36-TC61-F7-3

3500K

410

380

450

CXM-4-35-95-36-TC61-F7-3

4000K

440

410

485

CXM-4-40-95-36-TC61-F7-3

 

CCT, CRI and R9 Values

Correlated Color Temperatures

XX Value

CRI

R91

2700K, 3000K, 3500K, 4000K, 5000K, 6500K

80

>80

>0

2200K, 2400K, 2700K, 3000K, 3500K, 4000K, 5000K, 6500K

90

>90

>50

2700K, 3000K

95

>95

>80

3500K, 4000K, 5000K

>70

 

Absolute Maximum Ratings

9 V

Parameter

Symbol

Value

Unit

Forward Current

Typical

If typ

480

mA

Maximum

If max

1600

Power Dissipation

Typical

Pd typ

4

W

Maximum

Pd max

7.5

Operating Case Temperature

Maximum

Tc

120

°C

Junction Temperature

Maximum

T

j

140

°C

 

18 V

Parameter

Symbol

Value

Unit

Forward Current

Typical

If typ

240

mA

Maximum

If max

800

Power Dissipation

Typical

Pd typ

4

W

Maximum

Pd max

7.5

Operating Case Temperature

Maximum

Tc

120

°C

Junction Temperature

Maximum

T

j

140

°C

 

36 V

Parameter

Symbol

Value

Unit

Forward Current

Typical

If typ

120

mA

Maximum

If max

400

Power Dissipation

Typical

Pd typ

4

W

Maximum

Pd max

7.5

Operating Case Temperature

Maximum

Tc

120

°C

Junction Temperature

Maximum

T

j

140

°C

 