GW CS8PM1.CM-KULQ-XX55-1-350-R18 4000K CRI 90 ams OSRAM's OSLON® SSL 80

GW CS8PM1.CM-KULQ-XX55-1-350-R18 4000K CRI 90 ams OSRAM's OSLON® SSL 80

- KULQ at 3500 K, XX55 at 4000 K — the 104 to 130 lm tier and the 121 to 150 lm bin sit on separate rows of the ordering table, and no single row carries both.
- Six brightness groups sold as four bands — KT 97–104, KU 104–112, LP 112–121, LQ 121–130, LR 130–140 and LS 140–150 lm, published as KTLP, KULQ, LPLR and LQLS, each three rungs wide.
- Two lifecycles inside one string — the 3500 K tier row is discontinued while the 4000 K row is in full production, so half of what the drawing names has already gone.
- An R9 floor of 50 behind a 90 CRI minimum — the deep-red figure that separates it from the CRI 80 grade.
- A 3.0 × 3.0 mm ceramic body with an 80° prefocused lens — 24.9 mg, moisture class 2, 600 per 180 mm reel, a cathode marking and an 8 kV human-body discharge rating.

Description

Product Introduction

 

 

The two halves of this reference live on separate rows of the ordering table, and neither row carries both. The 104 to 130 lm band is real - the table prints it as GW CS8PM1.CM-KULQ-XX56-1, Q65112A0977 - but at 3500 K, and that row now reads discontinued. The 4000 K colour bin is real as well, on GW CS8PM1.CM-LQLS-XX55-1 - ordering number Q65113A9958, band 121 to 150 lm, full production. Joined, they describe a part ams OSRAM does not build.

 

What remains is a choice between two routes rather than a substitution. Hold 4000 K and the output floor climbs from 104 lm to 121 lm, the two windows meeting in a single group, LQ at 121 to 130 lm. Hold the 104 lm floor instead and the colour temperature drops 500 K, onto a row on its way out.

 

The ladder explains why. Six groups run from KT at 97 to 104 lm up to LS at 140 to 150 lm, sold as four bands - KTLP, KULQ, LPLR and LQLS - each three rungs wide, so consecutive bands share two of their three rungs.

Key Product Features

 

 

1. Two Rows, One Reference
KULQ is a real tier and XX55 is a real colour bin, but the table prints them on separate lines. The tier belongs to the 3500 K row Q65112A0977, which is discontinued; the bin belongs to the 4000 K row Q65113A9958, which is in production. A purchase order built from the drawing's string therefore asks for a device that has never been catalogued.


2. A Six-Rung Ladder Sold as Four Overlapping Bands
The brightness table defines six groups and the ordering table sells four pairs of them. Each pair spans three consecutive rungs - KTLP covers KT through LP, KULQ covers KU through LQ, and so on to LQLS - so adjacent bands share two of their three rungs and one delivered part can satisfy either of two ordering strings.


3. 3500 K Is the Only Colour Point With a Choice
Three of the six rows sit at 3500 K: 97 to 121 lm, 104 to 130 lm and 112 to 140 lm. The 2700 K, 3000 K and 4000 K points each carry one row only. Choice of output tier is a property of the colour temperature rather than of the family, and at 4000 K the tier is fixed at the top of the ladder.


4. The CRI 90 and CRI 80 Ladders Share Four Letters
Both variants define LP, LQ, LR and LS with identical limits, so an LS part is 140 to 150 lm whichever grade is ordered. The ladders diverge at the ends: the CRI 90 device adds KT and KU below and stops at LS, while the CRI 80 device opens at LP and adds LT and LU above.


5. A Thermal Figure Labelled Both Typical and Maximum
The characteristics table prints the junction-to-solder resistance as 4.2 K/W typical, and glossary note 8 describes the thermal-resistance maximum as a six-sigma statistic used for derating. The number is the same; the reading is not, and a board sized on the conservative one carries margin the other does not offer.

 

Parameter Typical Value
Manufacturer ams OSRAM
Product Series OSLON® SSL 80
Ordering Code Q65113A9958 (the live 4000 K row is LQLS-XX55-1; the KULQ-XX55 string is not listed)
Colour Temperature (CCT) 4000 K (bin XX55), centre Cx 0.3818 / Cy 0.3796, orientation 53.4°
Luminous Flux (IF = 350 mA, Tj = 85 °C) 121 to 150 lm (LQ through LS)
Forward Voltage (IF = 350 mA) 2.85 V typ., five groups spanning 2.70 to 3.20 V
Forward Current 100 mA min. / 1300 mA max. continuous / 2000 mA surge on a 10 µs pulse
Viewing Angle 80° (prefocused)
Colour Rendering Index 90 min., 92 typ., R9 50 min.
Thermal Resistance (RthJS) 4.2 K/W, an electrical figure quoted at ηe = 20 %

Application Fields

 

 

Three fields are named in the datasheet - indoor lighting, entertainment, and outdoor and industrial work. At a neutral 4000 K with R9 held at 50, the fixtures that suit it best are the ones judging colour rather than setting a mood. Typical specifications include:

 

- Retail general and shelf lighting – sales floors and gondola ends, where merchandise is compared under the light rather than merely seen.
- Fresh-food and delicatessen counters – produce, bakery and butchery displays a customer assesses before buying.
- Office and education task lighting – desks, classrooms and reading rooms, where a neutral point keeps paper and screens in balance.
- Medical examination and consulting rooms – the neutral end of the range, chosen for tissue assessment rather than patient comfort.
- Workshop and bench inspection – assembly and repair benches where a small colour error becomes a rejection.
- Museum and conservation display – vitrines and case lighting where the object, not the ambience, is the subject.
- Studio and photographic fill – a controlled neutral source for still and video work at close range.
- Machine-vision and inspection illumination – line-side imaging that depends on a repeatable colour point and a defined beam.
- Warehouse and picking areas – aisle and shelf lighting at a point that keeps labels and packaging legible.
- Architectural and façade washing – outdoor and industrial work, the datasheet's third field, at a neutral rather than a warm tone.

Why Choose Gainer LED?

 

 

Price is the easiest part of a component order to get right, and the least likely to be remembered afterwards.


- A single product category since 2012
Nothing but branded optoelectronic components has passed through this business in fourteen years, so a question about a bin, a document or a reel is answered from the trade rather than from a catalogue.


- One shipment, one invoice
A build that names three makers leaves on a single set of export papers, so the customs file and the accounts entry are prepared once rather than three times.


- Substitutions offered, never assumed
Where a reference cannot be supplied, the alternative is named with its own specification and its own band, so nothing is swapped without the buyer's agreement.


- Terms stated before they are asked for
Reel size, break quantity and the shipping window sit inside the offer, so a planner can book a slot without a follow-up exchange.


- Paperwork that travels with the goods
Declarations and lot documentation are issued alongside the shipment rather than reconstructed afterwards, which keeps a customer's audit file complete.

FAQ

Q: The listing we were given shows a code the manufacturer's table does not carry. What should we publish instead?

A: Publish the live 4000 K row - GW CS8PM1.CM-LQLS-XX55-1, ordering number Q65113A9958, graded 121 to 150 lm at 350 mA. The string in the listing joins the 104 to 130 lm tier, which the table prints at 3500 K, to the 4000 K colour bin, which the table prints with a different tier. Neither half is wrong on its own; only the join is.

Q: The datasheet calls the thermal resistance a typical figure in one table and a maximum in the glossary. Which goes into our design file?

A: Treat it as the maximum. Glossary note 8 states that the thermal-resistance maximum is a six-sigma statistic used for derating, so the 4.2 K/W carries a worst-case reading rather than a central one, and a board sized on it is conservative. A 20 % radiant-efficiency premise, rather than a measured value, sits behind the same number.

Q: Two CRI grades carry the same flux letters at 4000 K. Can we treat the brightness as equivalent?

A: Only inside the letters they share. Both datasheets define LP, LQ, LR and LS with identical limits, so an LS part is 140 to 150 lm whichever grade is ordered. The bands around those letters differ: the CRI 90 code at 4000 K spans LQ to LS, while the CRI 80 code at the same point spans LS to LU. Compare the letters, not the grade.

Q: One row in the ordering table carries a different ordering-number prefix from the other five. Is it a different device?

A: No. The prefix is assigned when a code is introduced, so a row added later carries a later block; Q65115A2797 is the 3500 K 112 to 140 lm entry and is an ordinary member of the same table. What separates the rows is the colour field and the flux band, not the number.

Q: The manufacturer's page gives the body height as 2.21 mm and a distributor listing says 2.13 mm. Which do we tool to?

A: Neither figure is contradicted by the document. Glossary note 9 sets drawing tolerances at ±0.1 mm unless the drawing states otherwise, and the two heights differ by 0.08 mm, which is inside that band. Tool the 3.0 × 3.0 mm footprint and take the height from the drawing itself.

 

Hot Tags: GW CS8PM1.CM-KULQ-XX55-1-350-R18 4000K CRI 90 ams OSRAM's OSLON® SSL 80, China GW CS8PM1.CM-KULQ-XX55-1-350-R18 4000K CRI 90 ams OSRAM's OSLON® SSL 80 manufacturers, suppliers, factory, LR E67F ABCB 46 G3R3 50 R18 Z, SFH 4726S, Osram SFH 4725AS, GW JTLPS1 CM JMKM XX56 1, 8 digit led display drivers, GW JTLMS1 EM G9H1 XX58 1 60 1 R33