Description
1-conductor female connector; CAGE CLAMP®; 1.5 mm²; Pin spacing 3.5 mm; 4-pole; 100% protected against mismating; 1,50 mm²; light gray
Female connector/socket, 734 series, with 0° conductor exit to the plug-in direction
The female connector/socket (item number 734-104) enables a seamless electrical installation. Rely on time-tested reliability when designing your device: PCB connectors offer a wide range of application possibilities. This female connector/socket requires stripping of insulation between 6 and 7 mm for the conductor connection. This product uses CAGE CLAMP® technology. The reliable and maintenance-free CAGE CLAMP® universal connection allows all types of conductors to be connected using a cage clamp without the need for any pretreatment. Crimping of wire end ferrules is therefore no longer necessary. The dimensions are (width x height x depth) (16.2 x 13.4 x 18.6) mm. Depending on the conductor type, the female connector/socket is suitable for conductor cross-sections from 0.08 mm² to 1.5 mm². Tin was used for the contact surface. This female connector/socket is actuated using an actuation tool. WAGO's MCS - "Multi Connection System" comprises a total of seven families with pitches from 2.5 mm to 10.16 mm and offers a wide range of application possibilities with a conductor cross-section range from 0.08 to 25 mm².
Connection data
| Clamping units | 4 |
| Total number of potentials | 4 |
| Number of connection types | 1 |
| Number of levels | 1 |
Connection 1
| Connection technology | CAGE CLAMP® |
| Actuation type | Operating tool |
| Actuation direction 1 | Operation parallel to conductor entry |
| Actuation direction 2 | Operation perpendicular to conductor entry |
| Solid conductor | 0.08 … 1.5 mm² / 28 … 14 AWG |
| Fine-stranded conductor | 0.08 … 1.5 mm² / 28 … 14 AWG |
| Fine-stranded conductor; with insulated ferrule | 0.25 … 1.5 mm² |
| Fine-stranded conductor; with uninsulated ferrule | 0.25 … 1.5 mm² |
| Note (conductor cross-section) | Terminating 1.5 mm² conductors is possible; however insulation diameter does not allow clamping units to be terminated in a row. |
| Strip length | 6 … 7 mm / 0.24 … 0.28 inches |
| Pole number | 4 |
| Conductor entry direction to mating direction | 0° |
Physical data
| Pin spacing | 3.5 mm / 0.138 inches |
| Width | 16.2 mm / 0.638 inches |
| Height | 13.4 mm / 0.528 inches |
| Depth | 18.6 mm / 0.732 inches |
Mechanical data
| Variable coding | Yes |
| Anti-rotation protection | Yes |
Plug-in connection
| Contact type (pluggable connector) | Female connector/socket |
| Connector (connection type) | for conductor |
| Mismating protection | Yes |
| Plugging without loss of pin spacing | No |
| Locking of plug-in connection | none |
Material data
| Note (material data) | Information on material specifications can be found here |
| Color | light gray |
| Material group | I |
| Insulation material (main housing) | Polyamide (PA66) |
| Flammability class per UL94 | V0 |
| Clamping spring material | Chrome-nickel spring steel (CrNi) |
| Contact material | Copper alloy |
| Contact plating | Tin |
| Fire load | 0,052MJ |
| Weight | 3,2g |
Environmental requirements
| Limit temperature range | -60 … +100 °C |
| Processing temperature | -35 … +60 °C |
Environmental Testing (Environmental Conditions)
| Test specification Railway applications – Rolling stock – Electronic equipment | DIN EN 50155 (VDE 0115-200):2022-06 |
| Test procedure Railway applications – Rolling stock equipment – Shock and vibration tests | DIN EN 61373 (VDE 0115-0106):2011-04 |
| Spectrum/Installation location | Service life test, Category 1, Class A/B |
| Function test with noise-like vibration | Test passed according to Section 8 of the standard |
| Frequency | f1 = 5 Hz to f2 = 150 Hz |
| Acceleration | 0.101g (highest test level used for all axes) |
| Test duration per axis | 10 min. |
| Test directions | X, Y and Z axes |
| Monitoring for contact faults/interruptions | Passed |
| Voltage drop measurement before and after each axis | Passed |
| Simulated service life test through increased levels of noise-like vibration | Test passed according to Section 9 of the standard |
| Frequency | f1 = 5 Hz to f2 = 150 Hz |
| Acceleration | 0.572g (highest test level used for all axes) |
| Test duration per axis | 5 h |
| Test directions | X, Y and Z axes |
| Extended test scope: Monitoring for contact faults/interruptions | Passed |
| Extended test scope: Voltage drop measurement before and after each axis | Passed |
| Shock test | Test passed according to Section 10 of the standard |
| Shock form | Half sine |
| Acceleration | 5g (highest test level used for all axes) |
| Shock duration | 30 ms |
| Number of shocks per axis | 3 pos. und 3 neg. |
| Test directions | X, Y and Z axes |
| Extended test scope: Monitoring for contact faults/interruptions | Passed |
| Extended test scope: Voltage drop measurement before and after each axis | Passed |
| Vibration and shock stress for rolling stock equipment | Passed |
Commercial data
| Product Group | 3 (Multi Conn. System) |
| PU (SPU) | 100 pcs |
| Packaging type | box |
| Country of origin | DE |
| GTIN | 4044918492478 |
| Customs tariff number | 85366990990 |
Product classification
| UNSPSC | 39121409 |
| eCl@ss 10.0 | 27-44-03-09 |
| eCl@ss 9.0 | 27-44-03-09 |
| ETIM 9.0 | EC002638 |
| ETIM 8.0 | EC002638 |
| ECCN | NO US CLASSIFICATION |
Environmental Product Compliance
| RoHS Compliance Status | Compliant,No Exemption |
Hot Tags: 734-104, China 734-104 manufacturers, suppliers, factory